1000kW 500KW*2 50Hz Natural Gas Generator Set

Fuel typeNatural gas
Equipment type
ED1000NG (Vertical Radiator Container Type
Generator)
Equipment configurationGas Generator Set, Radiation System, Synchronization System, Steel Base, 30Feet Container
Genset compliance with
 standard
ISO3046,ISO8528,GB2820, CE

Description

1000KW ED1000NGB  Natural Gas Generator Set  2*500kW Synchronized 50Hz

Model #: ED1000NGB

Main configuration & Feature

  • Highlyefficient gas engine;
  • ACsynchronous alternator;
  • Gassafety train and gas protection device against leakage;
  • Coolingsystem and temperature control system enable the generator to work at ambient temperature up to 50℃;
  • Industrialsilencer can decrease noise to 12-20dB(A);
  • Advancedengine control system, including: ignition system, detonation control system, speed control system,

          air/fuel ratio control system, protecting system and cylinder temperature control system;

  • Independentelectrical control cabinet with optional remote monitoring system;
  • Multi-functionalcontrol system with easy operation
  • Datacommunication interfaces integrated into control system
  • Monitoringbattery voltage and charging automatically

Generator Set Data

Fuel type
ED1000NG (Vertical Radiator Container Type
Generator)
Equipment configurationGas Generator Set, Radiation System, Synchronization System, Steel Base, 30Feet Container
Genset compliance with standardISO3046,ISO8528, GB2820, CE, CSA, UL, CUL

 

Continuous output
Load
50%
75%
100%
Power output                       KW
500
750
1000
Fuel consumption                KW
1412
1984
2646
Efficiency in mains parallel mode
Continuous output
50%
75%
100%
Electrical efficiency               %
35.4
37.8
38.0
Current (A)/ 600V / F = 0.8
902
1353
1804

Note:

The above indicators are effective under specific gas source conditions, please consult customer service for details.

Single Engine Generator Data
Connection type
Star, 3P4h
Frequency   
Hz
50
Power factor
0.7
Class (H) KVA power rating
KVA
720
Generator voltage 
V
600
Current  
A
660
Startup mode
DC24V electric start
Unit operation type
One-key automatic start and stop
Performance Data
Allowed Overload (1.1) Time (H)
1
Voltage Setting Range
≥±5%
Steady-state voltage deviation
≤±1%
Transient voltage deviation
-15%~20%
Voltage Recover Time (s)
≤4
Voltage fluctuation
1%
Steady State Frequency Regulation
±0.5%
Transient State Frequency Regulation
-15%~12%
Frequency Recover Time (s)
≤3
Steady state band
0.5%
Recover Time (s)
0.5
Sinusoidal distortion rate of line voltage waveform
≤ 5%
Manufacturing Technology:
  • Special welding base, built-in shock absorber, overall hoisting;
  • High-grade paint layer, wear-resistant and scratch-resistant, bright and durable
Certificates & Standards
  • ISO3046,ISO8528,GB2820
  • BS5000PT99,AS1359,CE
IEC34ISO9001:2016

Alternator Data
Gas Engine Data
Brand
Mecc Alte
Brand
Deutz
Model
720kVA/600V
Model
12V132NG
Rated Voltage(V)
600
Engine Type
V-12, Turbocharger
Rated Power (H) (kW )
500
Bore*Stroke(mm)
132 mm×145 mm
Rated Capacity (H)
(kVA)
720
Displacement(L)
23.8
Efficiency (%)
95.8
Compression Ratio
11.5
Power factor
0.7
Rated Output Power
535kW/1500rpm
Connection
D/Y
Max Lubricant Consumption(g/kW.h)
0.3

 

Rotor insulation class

Rated temperature rise

Excitation method

rpm(min-1)

Housing Protection Grade
H

 F
Brush-less 

1500

IP23
Minimum Air Input (kg/h)

Ignition

Fuel Control

Commissioning

Cooling Method
4800
Electronically controlled single-cylinder
 independent
 high-energy ignition
Lean burn, close-loop control
Electrical

Forced water cooling
  • Alternator conforms to GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359.
    If the rated voltage varies by ±2%, an Automatic Voltage Regulator (AVR) shall be used.
  •  Lubricant and coolant should be selected according to factors such as local ambient temperature and air pressure.

Detailed introduction of the unit:

Start method

The unit uses DC 24V electric starter, and the unit starting power and control power use 24V battery packs. 
The battery pack is supplied by the supplier in a complete set, no need for grid electricity or diesel generator set.

Emergency stop

A manual emergency shutdown is installed on the side of the unit, and the system is also equipped with an automatic 
emergency shutdown function in case of an accident to respond quickly and promptly in.

Genset operation

The unit can realize: one-button control, automatic adjustment of air-fuel ratio, automatic power factor control, 
automatic loading and unloading, etc.

Unit control system; the unit control cabinet is a floor cabinet structure with a single control panel. The control cabinet
 is equipped with controllers, switches, various display instruments, adjustment buttons, unit protection indicator lights, 
emergency stop buttons, etc., which are used to control and monitor the working status of the generator set.
Genset failure protection

The control system has: overload, over-current, short-circuit, reverse power, under-frequency, over-frequency, under-voltage, 
over-voltage, over-speed and other engine complete protection, and sends out sound and light alarm 
signals. In the event of minor engine failures (such as high cooling water temperature, low oil pressure, 
overload, failure to start, etc.), light and sound alarms should be issued, and manual or automatic 
parking is allowed. In the event of a major engine failure (such as high temperature, low oil pressure,
 overspeed, etc.), it should automatically stop immediately and issue an audible and visual alarm.

Silent Canopy (Optional)

The silent type products use surface sound-absorbing egg cotton + second-layer sound-absorbing rubber and plastic cotton
 to reduce noise, moisture-proof and flame-retardant, non-toxic and harmless. The door seams and welts of the silent 
products are all made of shock-absorbing sponge strips, which are sound- absorbing and shock-absorbing, and rainproof and
 heat-insulating.
SOP
                         Engine                                  lternator                        Canopy & Base                            Control Cabinet
Gas EngineAC AlternatorSteel Base(Open type)Main breaker
Ignition SystemH Grade InsulationEngine bracketParalleling controlsystem
Lambda Controller

Electronic governor actuator Electrical start motor Vertical radiator

IP23

AVR

PF Controller

Vibration Isolator Cabinet (silent unit, waterproof unit) Dust filter (optional)Parallel controller

communication interface

Electrical switchgear

Automatic Charging System/Battery System

Gas supply system                              Lubrication system            Standard voltage                  Induction / exhaust system
Gas safety train
Oil filter
400V/230V@50Hz
Air filter
Gas leakageprotection
Daily auxiliary oiltank
400/230V
Exhaust silencer
415/240V
Air/fuel mixer
Auto refilling oilsystem
Exhaust bellows

Optional

EngineAlternatorLubricant System
Coarse air filter

Temper safety control valve Jacket water preheater

AC Alternator: StamfordBig Lubricant Tank Fuel Pump
Electrical systemGas supply systemVoltage
Remote Monitoring & control system
ATS control cabinet
Main Power Supply Output Distribution
Barometer Gas filtration
Decompression system Gas 
pretreatment alarm system
600V
6.3kV
10.5kV
Service & DocumentsDischarge SystemWaste Heat Recovery System
Service tools Spare partsSCR DeNox Protection Guard Silencer

Exhaust treatment

Emergency radiator Heat recovery system Heat storage tank

Control System
Standard Configuration
Engine Control:

Lambda closed-loop control ignition system

Electronic Governor Actuator Start Control

speed control load control

Generator Control: Power Control Speed control (synchronous)

Load Sharing (Island Mode) Voltage Control

Voltage regulation Other: Fan control (synchronous)

Voltage Control (Island Mode) Reactive distribution (island type)

Precaution & Monitoring
Genset Voltage Genset Frequency

AC Generator Data: U, I, Hz, kW, kVA, kVAr, PF, kWh, kVAh

rpm

Engine operation time

Inlet pressure Temperature Lubricant pressure

Lubricant temperature

Coolant temperature Exhaust Oxygen test Ignition status checkCoolant temperature Fuel inlet pressure Heat exchanger pressure and temperature
 
Protection Function
engine protection low oil pressure speed protection

overspeed/short circuit Startup failed

Loss of speed signal

generator protection

2 times reverse power 2X overload

4X over current 1X overvoltage 1 undervoltage

1 over/under frequency

1 unbalanced current

Bus/Trunk Protection 1 overvoltage

1 undervoltage

1 over/under frequency

1 phase sequence

1 fault alarm

system protection Alarm protection function

High coolant temperature charging failure

emergency shutdown

 

ED1000NGB (Weather Proof Canopy)
Dimensions (L * W * H) mm
9000×2438×2591(2950 with silencer)
Weight
13000kg
Painting
Premium Powder Coating(RAL 9016 & RAL 5017 & RAL 9017 )
ED1000NGS (Silence Canopy)
Dimensions (L * W * H) mm
9000×2438×2591(4200 with Horizontal Radiator)
Weight
15000kg
Painting
Premium Powder Coating(RAL 9016 & RAL 5017 & RAL 9017 )

Note: The above dimensions and weights are for standard products only and may change, the final data is subject to the drawings.

If you have actual procurement needs, please contact us to develop a detailed plan for you.