Description
1000KW ED1000NGB Natural Gas Generator Set 2*500kW Synchronized 50Hz
Model #: ED1000NGB
Main configuration & Feature
- Highlyefficient gas engine;
- ACsynchronous alternator;
- Gassafety train and gas protection device against leakage;
- Coolingsystem and temperature control system enable the generator to work at ambient temperature up to 50℃;
- Industrialsilencer can decrease noise to 12-20dB(A);
- Advancedengine control system, including: ignition system, detonation control system, speed control system,
air/fuel ratio control system, protecting system and cylinder temperature control system;
- Independentelectrical control cabinet with optional remote monitoring system;
- Multi-functionalcontrol system with easy operation
- Datacommunication interfaces integrated into control system
- Monitoringbattery voltage and charging automatically
Generator Set Data
Fuel type | ED1000NG (Vertical Radiator Container Type Generator) |
Equipment configuration | Gas Generator Set, Radiation System, Synchronization System, Steel Base, 30Feet Container |
Genset compliance with standard | ISO3046,ISO8528, GB2820, CE, CSA, UL, CUL |
Continuous output | |||
Load | 50% | 75% | 100% |
Power output KW | 500 | 750 | 1000 |
Fuel consumption KW | 1412 | 1984 | 2646 |
Efficiency in mains parallel mode | |||
Continuous output | 50% | 75% | 100% |
Electrical efficiency % | 35.4 | 37.8 | 38.0 |
Current (A)/ 600V / F = 0.8 | 902 | 1353 | 1804 |
Note:
The above indicators are effective under specific gas source conditions, please consult customer service for details.
Single Engine Generator Data
Connection type | Star, 3P4h | |
Frequency | Hz | 50 |
Power factor | 0.7 | |
Class (H) KVA power rating | KVA | 720 |
Generator voltage | V | 600 |
Current | A | 660 |
Startup mode | DC24V electric start | |
Unit operation type | One-key automatic start and stop |
Performance Data
Allowed Overload (1.1) Time (H) | 1 |
Voltage Setting Range | ≥±5% |
Steady-state voltage deviation | ≤±1% |
Transient voltage deviation | -15%~20% |
Voltage Recover Time (s) | ≤4 |
Voltage fluctuation | 1% |
Steady State Frequency Regulation | ±0.5% |
Transient State Frequency Regulation | -15%~12% |
Frequency Recover Time (s) | ≤3 |
Steady state band | 0.5% |
Recover Time (s) | 0.5 |
Sinusoidal distortion rate of line voltage waveform | ≤ 5% |
Manufacturing Technology:
- Special welding base, built-in shock absorber, overall hoisting;
- High-grade paint layer, wear-resistant and scratch-resistant, bright and durable
Certificates & Standards
- ISO3046,ISO8528,GB2820
- BS5000PT99,AS1359,CE
IEC34ISO9001:2016
Alternator Data | Gas Engine Data | ||
Brand | Mecc Alte | Brand | Deutz |
Model | 720kVA/600V | Model | 12V132NG |
Rated Voltage(V) | 600 | Engine Type | V-12, Turbocharger |
Rated Power (H) (kW ) | 500 | Bore*Stroke(mm) | 132 mm×145 mm |
Rated Capacity (H) (kVA) | 720 | Displacement(L) | 23.8 |
Efficiency (%) | 95.8 | Compression Ratio | 11.5 |
Power factor | 0.7 | Rated Output Power | 535kW/1500rpm |
Connection | D/Y | Max Lubricant Consumption(g/kW.h) | 0.3 |
Rotor insulation class Rated temperature rise Excitation method rpm(min-1) Housing Protection Grade | H F Brush-less 1500 IP23 | Minimum Air Input (kg/h) Ignition Fuel Control Commissioning Cooling Method | 4800 Electronically controlled single-cylinder independent high-energy ignition Lean burn, close-loop control Electrical Forced water cooling |
- Alternator conforms to GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359.If the rated voltage
varies by ±2%, an Automatic Voltage Regulator (AVR) shall be used.
- Lubricant and coolant should be selected according to factors such as local ambient temperature and air pressure.
Detailed introduction of the unit: Start method The unit uses DC 24V electric starter, and the unit starting power and control
power use 24V battery packs. The battery pack is supplied by the supplier in a complete set, no need for grid electricity or diesel
generator set. Emergency stop A manual emergency shutdown is installed on the side of the unit, and the system is also
equipped with an automatic emergency shutdown function in case of an accident to respond quickly and promptly in. Genset
operation The unit can realize: one-button control, automatic adjustment of air-fuel ratio, automatic power factor control,
automatic loading and unloading, etc. Unit control system; the unit control cabinet is a floor cabinet structure with a single
control panel. The control cabinet is equipped with controllers, switches, various display instruments, adjustment buttons,
unit protection indicator lights, emergency stop buttons, etc., which are used to control and monitor the working status of
the generator set.
Genset failure protection The control system has: overload, over-current, short-circuit, reverse power, under-frequency,
over-frequency, under-voltage, over-voltage, over-speed and other engine complete protection, and sends out sound and
light alarm signals. In the event of minor engine failures (such as high cooling water temperature, low oil pressure, overload,
failure to start, etc.), light and sound alarms should be issued, and manual or automatic parking is allowed. In the event of a
major engine failure (such as high temperature, low oil pressure, overspeed, etc.), it should automatically stop immediately
and issue an audible and visual alarm. Silent Canopy (Optional) The silent type products use surface sound-absorbing egg
cotton + second-layer sound-absorbing rubber and plastic cotton to reduce noise, moisture-proof and flame-retardant, non-toxic
and harmless. The door seams and welts of the silent products are all made of shock-absorbing sponge strips, which are
sound- absorbing and shock-absorbing, and rainproof and heat-insulating.
SOP | |||
Engine lternator Canopy & Base Control Cabinet | |||
Gas Engine | AC Alternator | Steel Base(Open type) | Main breaker |
Ignition System | H Grade Insulation | Engine bracket | Paralleling controlsystem |
Lambda Controller Electronic governor actuator Electrical start motor Vertical radiator | IP23 AVR PF Controller | Vibration Isolator Cabinet (silent unit, waterproof unit) Dust filter (optional) | Parallel controller communication interface Electrical switchgear Automatic Charging System/Battery System |
Gas supply system Lubrication system Standard voltage Induction / exhaust system | |||
Gas safety train | Oil filter | 400V/230V@50Hz | Air filter |
Gas leakageprotection | Daily auxiliary oiltank | 400/230V | Exhaust silencer |
415/240V | |||
Air/fuel mixer | Auto refilling oilsystem | Exhaust bellows |
Optional
Engine | Alternator | Lubricant System |
Coarse air filter Temper safety control valve Jacket water preheater | AC Alternator: Stamford | Big Lubricant Tank Fuel Pump |
Electrical system | Gas supply system | Voltage |
Remote Monitoring & control system ATS control cabinet Main Power Supply Output Distribution | Barometer Gas filtration Decompression system Gas pretreatment alarm system | 600V 6.3kV 10.5kV |
Service & Documents | Discharge System | Waste Heat Recovery System |
Service tools Spare parts | SCR DeNox Protection Guard Silencer Exhaust treatment | Emergency radiator Heat recovery system Heat storage tank |
Control System
Standard Configuration | |||
Engine Control: Lambda closed-loop control ignition system Electronic Governor Actuator Start Control speed control load control | Generator Control: Power Control Speed control (synchronous) Load Sharing (Island Mode) Voltage Control | Voltage regulation Other: Fan control (synchronous) Voltage Control (Island Mode) Reactive distribution (island type) | |
Precaution & Monitoring | |||
Genset Voltage Genset Frequency AC Generator Data: U, I, Hz, kW, kVA, kVAr, PF, kWh, kVAh | rpm Engine operation time Inlet pressure Temperature Lubricant pressure Lubricant temperature | Coolant temperature Exhaust Oxygen test Ignition status check | Coolant temperature Fuel inlet pressure Heat exchanger pressure and temperature |
Protection Function
engine protection low oil pressure speed protection overspeed/short circuit Startup failed Loss of speed signal | generator protection 2 times reverse power 2X overload 4X over current 1X overvoltage 1 undervoltage 1 over/under frequency 1 unbalanced current | Bus/Trunk Protection 1 overvoltage 1 undervoltage 1 over/under frequency 1 phase sequence 1 fault alarm | system protection Alarm protection function High coolant temperature charging failure emergency shutdown |
ED1000NGB (Weather Proof Canopy) | |
Dimensions (L * W * H) mm | 9000×2438×2591(2950 with silencer) |
Weight | 13000kg |
Painting | Premium Powder Coating(RAL 9016 & RAL 5017 & RAL 9017 ) |
ED1000NGS (Silence Canopy) | |
Dimensions (L * W * H) mm | 9000×2438×2591(4200 with Horizontal Radiator) |
Weight | 15000kg |
Painting | Premium Powder Coating(RAL 9016 & RAL 5017 & RAL 9017 ) |